Replacement / Renovation
92 VELUX
6
Replacement of roof window in slated roof
Use flashing EDL when replacing an old window with a new one
in roofs with slates. In most cases, the installation instructions for
flashing EDL can be followed.
If it is either not desirable or not possible to remove the slates,
follow this procedure:
REMOVING THE OLD WINDOW
1. Remove the window sash and all window covers.
2. Saw the side frames and remove carefully.
3. Carefully draw out side soakers and top and bottom flashing
sections. If the components are stuck in slate putty, loosen the
individual slate layers carefully from the flashing components
with a hand saw.
Remove putty from between the slate layers with the hand saw.