3
VELUX 39
Integration – more windows
Additional elements below roof window
ADDITIONAL ELEMENTS GIL/GIU IN TWIN INSTALLATION
Two roof windows each with additional elements GIL/GIU can be
installed with a frame distance of 18 mm using support rafter EBY
and a variant of twin flashing EB-.
Twin flashing EB- must be ordered as a special product.
Follow these guidelines during installation:
1. Prepare hole and install necessary trimmers.
Width: X mm + 18 mm + X mm + 50 mm.
Height: Y mm + 920 mm + 45 mm.
X mm = window width, Y = window height
2. Install support rafter EBY according to instructions supplied
with EBY.
3. Install frame insulation collar from installation set BDX 2000
with extension pieces BDX W34 according to instructions sup-
plied.
4. Install and adjust windows.
5. Connect windows to underfelt with underfelt collar BFX and
position drainage gutter immediately above upper trimmer to
which the support rafter is fixed.
6. Install flashing and fit covers according to instructions supplied
with additional elements GIL/GIU and the flashing.
It is also possible to integrate three windows side by side provided
that the total width of the window combination with high-lying
middle gutters does not exceed 2780 mm.