Replacement / Renovation
88 VELUX
6
Roof renovation
When changing from one roofing material to another, the position
of the new roof windows may have to be shifted slightly. Changed
batten spacing may require that the position of the window is
moved upwards/downwards to allow for correct installation and
relationship to the new roofing material.
To be able to maintain the interior opening without having to fill
any gap between lining and interior opening, adjust the angle of the
top or bottom element of the VELUX lining (screws lines 1 and 4
below refer to the template supplied with the lining).
max 110 mm
max 110 mm
max 180 mm
max 180 mm
A
B
A
B
B
A
A
B
60° ROOF PITCH
The window can be lowered up to 110 mm.
Position the top element (A) in screw line
4. If the window is raised the lining cannot
cover the interior opening.
45° ROOF PITCH
The window can be raised up to 180 mm.
Position the bottom element (B) in screw
line 1.
45° ROOF PITCH
The window can be lowered up to 180 mm.
Position top element (B) in screw line 1.
15° ROOF PITCH
The window can be raised up to 110 mm.
Position bottom element (A) in screw line 4.
The lining cannot cover the interior opening
if the window is recessed into the roof
opening, ie with flashing EDL.