Przeglądanie stron 43
Integration – more windows
44 VELUX
3
Installation along roof ridge
When choosing flashing for installations along roof ridge, the sim-
plest solution is to use standard flashings (EDW, EDL, EDS) on each
side of the roof combined with a roof ridge kit (EKW --0 --88) to
ensure a watertight and harmonious integration over the ridge.
In case of more windows installed side by side, standard combi
flashings (EKW, EKL, EKS) are used in combination with one roof
ridge kit for each pair of windows over ridge.
Whether it is single windows or windows in
combination, the top flashing sections must
be adjusted depending on the distance "A".
The distance "A" must be 80-200 mm and
the roof pitch 15°-5.
Note! Roof ridge kit (EKW --0 --88)
requires a ridge board to support the roof
ridge (especially in slate roofs).
If distance "A" is 200 mm or more, the
standard flashing can be used without any
adjustment. There is enough space for the
top flashing sections and the ridge tiles can
continue uninterrupted.
To make it possible to install the windows
closer to each other, use VELUX over
ridge flashing. This flashing connects two
windows of the same width across the ridge
and makes it possible to position the top
frames of the windows close to the ridge.