Installation of a roof window
18 VELUX
2
Establishing opening
REMOVING SASH
If installing the window from the inside the
sash must be removed.
Place the sash on a clean and even surface.
Installations from the outside can be carried
out with the sash in place.
INSTALLATION BRACKETS
Installation brackets are supplied with
the window or flashings for some specific
installations.
Window heights from -08 (1400 mm) and
upwards are supplied with additional instal-
lation brackets to be fitted at the middle of
the side frames.
The brackets must be fitted to the frame
prior to positioning the window in the roof.
Some products and combinations require
special brackets, eg:
When the window is installed with
recessed flashings EDN and EDJ, special
brackets are supplied with the flashing.
With some combinations of windows and
flashings, special brackets are supplied ei-
ther with the additional window elements,
eg GIL, VFE, or with the flashing, eg EBW.